Quick Answer · Altech Electrical

How Do I Know If I Have Three Phase Power?

Count the service fuses on your meter board, or look at the width of the main switch. Three service fuses, or a main switch three poles wide, means three phase power. One of each means single phase.

Meter box with three service fuses in a row above two meters and the switchboard
Three service fuses on the meter board means three phase power.

Check 1: count the service fuses

A service fuse is a large black rectangular fuse. They are generally easy to spot on the main switchboard or meter board.

  • One service fuse: single phase
  • Two service fuses: two phase
  • Three service fuses: three phase

Check 2: look at the main switch

The width of the main switch tells the same story. A single phase main switch is one pole wide. A three phase main switch is three poles wide.

Main switches are usually on the meter board. Larger premises and unit blocks can also have one on each sub-board.

Things that can mislead you

A meter marked "3 phase" does not prove it. A three phase capable meter can have only one or two phases connected. Check the service fuses and the main switch, not the wording on the meter.

The number of meters can mislead too. You can have one more meter than you have phases. The usual reason is separately metered off-peak hot water.

Two phase power exists as well. Two phase supplies are also quite common in Australia. They have two service fuses, not one or three.

Both checks are done by looking only. Our page on single phase and three phase power explains the difference, and our switchboard upgrades service covers upgrades.

Common questions

Does a three phase meter mean I have three phase power?

Not necessarily. A three phase capable meter can have only one or two phases connected, so check the service fuses and the main switch.

How many service fuses does three phase power have?

Three. A single phase supply has one and a two phase supply has two.

Can I have more meters than phases?

Yes. An extra meter is usually there for separately metered off-peak hot water.