In a new home, yes. New roofs are sealed and lined with sarking, so the Building Code requires the air to be ducted outside. Some older homes have tiled roofs without sarking, where a fan may exhaust into the roof space, but ducting outside is still worth considering.
What the Building Code says
The Building Code of Australia sets out two situations. The type of roof decides which one applies.
If the roof is lined with sarking, usually a silver insulation paper, the air must be ducted to the outside.
If the roof has no sarking and is clad with tiles or decking that let enough air escape, a ceiling fan can exhaust into the roof space.
New homes
New homes are built to energy efficiency rules, so their roofs are sealed. That means the exhaust must be ducted outside.
Moist air pushed into a sealed roof has no way out. Over time it can corrode metal, rot timber and loosen nails as the timber swells. It can also make cladding rot or swell, which is costly to fix.
Older homes
An older home may have a tiled roof with no sarking under the tiles. Small gaps between the tiles let air move in and out, so moist air can escape.
You can still duct the fan outside, and you may want to. It is often easy when the roof space is roomy and an eave vent can be fitted.
Ways to duct a fan outside
There are several common options:
- A ductable ceiling fan connected to an eave vent with flexible ducting.
- A ductable ceiling fan connected to a cowl on the roof.
- An inline fan in the roof space, linked to an intake vent in the bathroom and an outside vent.
- A roof-mounted fan with ducting down to the bathroom, for rooms directly below the roof.
- A fan that vents straight out through a wall or window.
Most ceiling-mounted fans suit a duct run of only a few metres. For more airflow, an inline or roof-mounted fan is the better choice. Our page on choosing a bathroom exhaust fan covers placement and airflow.
A hardwired fan must be installed by a licensed electrician. For help, see our exhaust fan installation service.